Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Hakkında
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Aygun, Sacid" seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Reliability of 3D-Printed Dynamic Scanners
    (IEEE, 2017) Gonultas, Burak Mert; Aygun, Sacid; Khayatzadeh, Ramin; Civitci, Fehmi; Gokdel, Yigit Daghan; Yelten, Mustafa Berke; Ferhanoglu, Onur
    3D-printed dynamic structures have arisen as a lower cost and easier to fabricate alternative to miniaturized sensor and actuator technologies. Here, we investigate the reliability of a selected 3D-printed laser scanner, which was initially designed for miniaturized confocal imaging, having 1 x 1 cm' footprint. The scan-line, 1 resonant frequency and quality factor of 3 devices were monitored for 100,000,000 (hundred million) cycles, and an average deviation of <6% was observed for all three parameters under investigation, for the devices under test. We conclude that 3D printed dynamic structures are promising candidates for a variety of applications, including optomedical imaging applications that demand disposable and low-cost scanning technologies.
  • Küçük Resim Yok
    Öğe
    Reliability Testing of 3D-Printed Electromechanical Scanning Devices
    (Springer, 2018) Gonultas, B. Mert; Savas, Janset; Khayatzadeh, Ramin; Aygun, Sacid; Civitci, Fehmi; Gokdel, Y. Daghan; Berke Yelten, M.
    Recent advances in the field of stereolithography based manufacturing, have led to a number of 3D-printed sensor and actuator devices, as a cost-effective and low fabrication complexity alternative to micro-electro-mechanical counterparts. Yet the reliability of such 3D-printed dynamic structures have yet to be explored. Here we perform reliability tests and analysis of a selected 3D-printed actuator, namely an electromechanical scanner. The scanner is targeted towards scanning incoming light onto the target, which is particularly useful for barcoding, display, and opto-medical tissue imaging applications. We monitor the deviations in the fundamental mechanical resonance, scan-line, and the quality factor on a number of scanners having different device thicknesses, for a total duration of 5 days (corresponding to 20-80 million cycles, depending on the device operating frequency). A total of 9 scanning devices, having 10 mm x 10 mm die size were tested, with a highlight on device-device variability, as well as the effect of device thickness itself. An average standard deviation of < similar to%10 (with respect to the mean) was observed for all tested parameters among scanners of the same type (an indicator device to device variability), while an average standard deviation of less than about 10 percent (with respect to the mean) was observed for all parameters for the duration of the entire test (as an indicator of device reliability), for a total optical scan angle of 5 degrees.

| İstanbul Bilgi Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Eski Silahtarağa Elektrik Santralı, Eyüpsultan, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Hakkında
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim